Fix for Opusdec output at 44.1kHz adding a pop at ~1 second.
authorGregory Maxwell <greg@xiph.org>
Sun, 3 Jun 2012 02:55:41 +0000 (22:55 -0400)
committerGregory Maxwell <greg@xiph.org>
Sun, 3 Jun 2012 02:55:41 +0000 (22:55 -0400)
commitac7490cbac7b5790a3ea2e9f7c8518af24336091
tree827b023208583394b0616d1bf18fffcb21813d49
parentf456150b74e6a86ff8dc9bab2dd114a713ad6f14
Fix for Opusdec output at 44.1kHz adding a pop at ~1 second.

Gainless, 2012, and Ivqcl on Hydrogenaudio reported and helped
identify an issue where opusdec was adding a click in 44.1kHz
output. This was becaue the loop needed to feed the resampler
for >1024 sample input wasn't accounting for the preskip and
was putting too many samples into the resampler on the first
packet. Eventually the output got ahead of the container
granpos and the decoder dropped some samples to catch up.

For 1 second pages, the opusenc default, dropped samples
happened just about at the 1 second mark.
src/opusdec.c